ACEY-BCT503-512H battery capacity grading machine is used to test the capacity of 18650 21700 26650 32700 etc battery cells through cycles of charging and discharging.
Brand :
ACEYItem No. :
ACEY-BCT503-512HCustomization :
OEM&ODM AvailableOrder(MOQ) :
1 SetCompliance :
CE CertifiedPayment :
T/T, L/C, PayPal, West Union, Alibaba Trade Assurance, EtcWarranty :
One Year Warranty With Lifetime SupportProduct Origin :
ChinaPackage :
Internal: Anti-Collision Protectio, External: Plywood CaseShipment :
By Air, Sea, Express, etc.5V 3A 512 Channels Cylindrical Battery Capacity Grading Machine For 18650 21700 26650 32700
Description
TACEY-BCT503-512H Lithium battery charge discharge tester is a kind of equipment used to test the capacity of Li-ion battery. It can simulate various working states of lithium battery during charging and discharging, and test and evaluate the electrical performance of the battery.
Parameters
Structure Of Equipment (Device) | |
Number of device channels | 512 Channels |
Size (width * depth * height) cm | 160*55*184 |
Clamp form | Cylindrical four-wire fixture |
Color of device | Dark grey |
Clamp center distance | 35mm |
Support battery height | Adjustable within 10-100mm range |
Working power | Three-phase five-wire system ac380v±10%, 50hz |
Working power dissipation | ≤14kw |
Work environment | Temperature 0-40 ℃, relative humidity ≤80% |
Heat-dissipating method | Natural wind intake and upward exhaust |
Channel Parameter | |
Voltage testing range | 0-5V, 1MV resolution |
Battery voltage range | Charge 0-4.5V: Discharge 4.5-2V |
Constant voltage range | 2.5V-4.5V |
Voltage accuracy | ±(1‰ reading +1‰ full) |
Current range | 30mA-3A,1mA, Reslution: 1mA |
Current accuracy | ±(1‰ reading +1‰ full) |
Control mode | Computer connection equipment work, Whole |
Machine Control | |
Software Function | |
Communication mode | Rs485, baud rate 57,600 |
Process set | Maximum 32 work steps and 256 cycles |
Charging mode | Constant current, constant voltage |
Charging cutoff condition | Voltage, current, time, capacity |
Discharge | Constant current |
Discharge cut-off condition | Voltage, time, capacity |
Time range | 0 - 30,000 minutes |
Time accuracy | ≤±1‰ |
Sampling inspection period | ≤8s |
Minimum data recording frequency | ≤8s |
Battery grading | By capacity, time, discharge platform, etc |
Data processing | Data, graphs, and loop diagrams |
Product Display