ACEY-BP24-100A200A BMS tester is used to test multiple functions of the protection board, including overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.
Brand :
ACEYItem No. :
ACEY-BP24-100A200ACustomization :
OEM&ODM AvailableOrder(MOQ) :
1 SetCompliance :
CE CertifiedPayment :
T/T, L/C, PayPal, West Union, Alibaba Trade Assurance, EtcWarranty :
One Year Warranty With Lifetime SupportProduct Origin :
ChinaPackage :
Internal: Anti-Collision Protectio, External: Plywood CaseShipment :
By Air, Sea, Express, etc.Product Description
ACEY-BP24-100A200A can detect the function of the lithium battery protection board and various performance indicators. It is especially suitable for factory inspections for mass production. It is developed using the principle of capacitor simulation battery charging and discharging, and has multiple functions. , Simple operation, fast detection speed, etc.
Features
Technical Parameters
Voltage | 120000mV |
Voltage resolution | 1mV |
Voltage accuracy | ±0.1% |
Discharging current | 0.1A ~200A |
Current resolution | 1mA |
Current accuracy | ±(0.1%) |
Other | The charging and discharging circuits are completely separated |
Output voltage of every cell | 500mV ~ 5000mV |
Input voltage of every cell | 500mV ~ 5000mV |
Voltage resolution | 1mV |
Voltage accuracy | ±0.05% |
Equalization current | 500mA |
Controllable analog current range | 0.1A -200A |
Controllable analog current accuracy | ±0.1% |
Maximum output voltage | 5000mV |
Consumption current measuring range | 1 ~ 5000uA |
Consumption current measuring resolution | 0.1uA |
Resistance | ACIR: 0-999mr |
Protection time | Overcurrent protection time:0-999ms; |
Short circuit protection time:0-999us | |
1 channel signal voltage output: | 500~5000mV |
AD/DA | AD:16bit DA:16bit |
Discharging model | CC |
24 analog cells | Input/output:500~5000mV, |
voltage accuracy:±0.1% | |
Communication rate | 2channels SBS communication |
rate:10~100Kbps | |
Others | Voltage sample:0~5000mV |
accuracy:±0.1% | |
Protect function | Overall protection (including reverse connection protection, voltage lower protection, voltage upper protection, and current upper protection), CC charging protection (abnormal voltage trend protection, abnormal charging current fluctuation protection, abnormal voltage fluctuation protection), CC discharge protection (including Voltage trend abnormal protection, discharge current fluctuation abnormal protection, voltage fluctuation abnormal protection) |
Communication | Interface RS232/DB9 |
Communication rate interface:38400 | |
All communication ports of the equipment are isolated, with lightning protection design | |
circuit structure | Modular structure, can be replaced and repaired in time with spare parts and spare parts. |
Machine architecture | Split cabinet |
Safety level | EN60950,GB4943 |
noise | As per IEC62040-3, ≤70dBA |
IP Level | IP20 |
Color | Subject to actual conditions |
lightning protection | GB17626 level:II |
Cooling | Forced air cooling, at least 20cm space between exit and entry |
Start pulse voltage | Equipment testing, the maximum allowable pulse voltage at the time of starting the execution process ≤ (set the number of test strings * set the single voltage)*110%, T≤500uS; |
Start pulse current | For equipment testing, the maximum allowable pulse current at the time of starting the overcurrent test process is less than or equal to the upper limit of the set overcurrent protection value*120%, T≤1mS |
Wiring method | Spring crimping |
Product Display
*Related Products
Tags :