ACEY-BP20-200A300A BMS tester is used to test multiple functions of the protection board, including overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.
Brand :
ACEYItem No. :
ACEY-BP20-200A300ACustomization :
OEM&ODM AvailableOrder(MOQ) :
1 SetCompliance :
CE CertifiedPayment :
T/T, L/C, PayPal, West Union, Alibaba Trade Assurance, EtcWarranty :
One Year Warranty With Lifetime SupportProduct Origin :
ChinaPackage :
Internal: Anti-Collision Protectio, External: Plywood CaseShipment :
By Air, Sea, Express, etc.Product Description
ACEY-BP20-200A300A can detect the function of the lithium battery protection board and various performance indicators. It is especially suitable for factory inspections for mass production. It is developed using the principle of capacitor simulation battery charging and discharging, and has multiple functions. , Simple operation, fast detection speed, etc.
Features
Technical Parameters
Self-consumption of single cell | 0--500 | ±0.1 | uA |
Self-consumption | 0--5000 | ±1 | uA |
Overcharge voltage | 500--5000 | ±1 | mV |
Overcharge recovery voltage | 500--5000 | ±1 | mV |
Overcharge voltage protection delay | 0--10000 | ±1 | mS |
Overdischarge voltage | 500--5000 | ±1 | mV |
Overdischarge recovery voltage | 500--5000 | ±1 | mV |
Overdischarge voltage protection delay | 0--10000 | ±1 | mS |
Overcharge protection current protection value | 0.1--200 | ±0.01 | A |
Overcharge protection current protection delay | 0--20000 | ±1 | mS |
Overdischarge protection current protection value | 0.1--300 | ±0.01 | A |
Overdischarge protection current protection delay | 0.1--20000 | ±1 | mS |
Equalization function opening voltage | 500--5000 | ±1 | mV |
Equalizing current | 1--500 | ±1 | mA |
Charging current | 0.1--120 | ±0.01 | A |
Discharging current | 0.1--120 | ±0.01 | A |
Charging time | 0--100 | ±1 | S |
Discharging time | 0--100 | ±1 | S |
The difference of single cell self-consume | 0-500 | ±0.1 | uA |
Resistance | 0-999 | ±1 | mΏ |
Short circuit protection time | 0--5000 | ±1 | uS |
The charging voltage of single cell | 500--5000 | ±1 | mV |
The discharging voltage of single cell | 500--5000 | ±1 | mV |
Open circuit voltage | 120000 | ±1 | mV |
Number of voltage analogs | 20 | 0 | PCS |
Product Display
*Related Products
Tags :