ACEY-BP32-300A500A Bms tester can detect the function of the lithium battery protection board and various performance indicators. It is especially suitable for factory inspections for mass production. Bms Testing Machine is developed using the principle of capacitor simulation battery charging and discharging, and has multiple functions. , Simple operation, fast detection speed, etc.
Brand :
ACEYItem No. :
ACEY-BP32-300A500ACustomization :
OEM&ODM AvailableOrder(MOQ) :
1 SetCompliance :
CE CertifiedPayment :
T/T, L/C, PayPal, West Union, Alibaba Trade Assurance, EtcWarranty :
One Year Warranty With Lifetime SupportProduct Origin :
ChinaPackage :
Internal: Anti-Collision Protectio, External: Plywood CaseShipment :
By Air, Sea, Express, etc.Product Description
1-32 Series Battery Management System Bms Testing Machine can meet the current market lithium ternary batteries, lithium iron phosphate batteries and cobalt acid battery protection plate test, with lithium ternary batteries, lithium iron batteries and cobalt acid battery test gear switching function.
The instrument requires connection to a computer, computer hardware configuration requirements for general office computers can be, the system generally requires XP system, the instrument and the computer using industry-standard 232 interface.
Parameters
No. | Function | Setting range | Testing accuracy | Unit |
1 | Single section self-consumption | 0--500 | ±0.1 | uA |
2 | Self-consumption | 0--5000 | ±1 | uA |
3 | Overcharge protection voltage | 500--5000 | ±1 | mV |
4 | Overcharge protection release voltage | 500--5000 | ±1 | mV |
5 | Overcharge protection delay time | 0--10000 | ±1 | mS |
6 | Over-discharge protection voltage | 500--5000 | ±1 | mV |
7 | Over-discharge protection release voltage | 500--5000 | ±1 | mV |
8 | Overcharge voltage protection delay time | 0--10000 | ±1 | mS |
9 | Overcharge current protection value | 0.1--500 | ±0.01 | A |
10 | Overcharge current protection delay time | 0--20000 | ±1 | mS |
11 | Overcharge current protection value | 0.1--800 | ±0.01 | A |
12 | Over discharge current protection delay time | 0.1--20000 | ±1 | mS |
13 | Equalizing opening voltage | 500--5000 | ±1 | mV |
14 | Equalizing Current | 1--500 | ±1 | mA |
15 | Charging Aging Current | 0.1--200 | ±0.01 | A |
16 | Discharge Aging Current | 0.1--200 | ±0.01 | A |
17 | Charging aging time | 0--30 | ±1 | S |
18 | Discharge current aging time | 0--60 | ±1 | S |
19 | Single section self-consumption difference | 0-500 | ±0.1 | uA |
20 | Resistance | 0-999 | ±1 | mΏ |
21 | Short circuit protection time | 0--5000 | ±1 | uS |
22 | Charging aging voltage | 500--5000 | ±1 | mV |
23 | Single discharge aging voltage | 500--5000 | ±1 | mV |
24 | Open circuit voltage | 102000 | ±1 | mV |
25 | Number of voltage simulations | 32 | 0 | PCS |
Product Display